Carrier 58PAV


Hi I have a 1998 carrier 58PAV furnace that the fan will run, and the flame or pilot will not come on. Is this my high limit switch or my hot surface ignitor. Please help Frozen Alberta Try and reset the unit by turning off the power for at least 5 min, then turn it back on and see what happens. Is the draft induction motor operating prior to any attempt to light? May need more info, see my posts to goldroad on carrier 58CTA no running in this forum. Some of those may help too. Depends. The sequence is as follows: Inducer fan comes on, pressure switch closes, ignitor glows, gas valve opens, flame ignites, flame sensor senses flam to keep it lit, then the circulation blower comes on. Where is the sequence stopping? The installation manual for your furnace is here: http://www.alltemp-hvac.com/58pa-15si.pdf You need to review the sequence of operation for your furnace when it tries to ight up and compare it with that described on page 12--- Heating Mode. See how far along your furnace gets before it goes not farther, and describe the sequence of operation you observe with care. Also --- if the diagnostic light blinks while the furnace is lighting up, please report that as well.








Related Posts:




  • Carrier furnace limit switch is tripping

    Carrier Furnace Limit Switch is TrippingI have Carrier Furnace model 58PAV111-20 The limit switch keeps trips after running for about 5 minutes. I can reset the switch but it trips. I looked on li...


  • Carrier furnace led codes where do i find their meaning

    Carrier Furnace LED Codes - where do I find their meaning?I have a Carrier Gas Furnace 58MXA100-20 that isn't working. After reset, it's LED code blinks 1short - 2long for a while then 2short - 3l...


  • Carrier furnacemanual reset

    Carrier Furnace-manual reset.our carrier furnace is 6 years old. we are getting the indicator light flashing for a manual reset(code 33 or 13). where or how do you do a manual reset. house blower...


  • Carrier weathermaker 8000 ignition problem

    Carrier Weathermaker 8000 Ignition ProblemThis is a model 58TMA085-16 furnace. When turning the furnace on it goes through the normal cycle of; Small blower comes on, soon igniter glows, soon gas...


  • Carrier oil furnace 58hu100101ca ignition not smooth

    Carrier Oil Furnace 58HU100101CA Ignition not SmoothInstalled all new in 1983 with Ducane Oil Burner, Webster fuel pump and Carrier Heat pump by licensed Carrier installer. Underground oil tank wi...