Replacing a honeywell aquastat relay
Is this very hard to replace? My heat wasn't working and I narrowed the problems down to the circ pump. It wasn't getting voltage, so I bypassed the Aquatsat and hooked the pump up to a cord. I have heat again. Is there some way to further test the Aquastat. It is a Honeywell aquastat relay type L8148A. thanks No, not terribly difficult if you have reasonable electrical and mechanical skills. With that aquastat, if there is a heat call and the burners fire, and the pump don't run, and you have no voltage at C1 and C2, there's really only one thing it can be... If you are doing it when it is cold outside, I would recommend having a spare well on hand or at least know where you can get one immediately if you need one. Mine was so corroded that I had to drain the boiler and replace the well. In case you don't know it, the well screws into the boiler and the relay probe fits in that well. Looking at the schem of my L8148A, it appears that the B (blue) terminal on the high limit is the same as the C1 (but on the other side of the relay ). Could be useful in a pinch, but I wonder if the extra current (burner plus circulator(s) now) would end up killing the relay entirely. One could set up an outboard relay using B (on the high limit) and C2 feeding it, then the circ(s) on a separate 110v feed from that. (Note: I havent tried this, this is only an assumption from the given schematic , so only test this if you know what you're doing, pre/post test connections and observations etc.) At least it would save ripping the aquastat/well out during the heat season ?? I have been having a problem with the boiler not coming on when the thermostats call for heat. When It first happened I turned the power switch to the boiler off and back on and the circulator pump came on and then the boiler fired up. This just started doing this, and at different times I will have to do the same thing to get the boiler to kick back on. When it does come on, the house heats up fine. Is it most likely the aquastat relay or could it be something else? Thanks
Related Posts:
Problem with the thermostat or aquastat relay honeywell l8148e
problem with the thermostat or aquastat relay (Honeywell L8148E)I have a Honeywell L8148E aquastat relay; forced hot water gas boiler. it will not come on. when jumping TV to T it will not come on...
Problem with replacement ra832a switching relay
Problem with replacement: ra832a switching relayHi everyone, this is my first time posting. Go easy on me! Breakdown of system: Baseboard water heating system, L8148E honeywell aquastat, 3 zones (...
Replacing honeywell zone valve motor morphed into add on wood boiler
Replacing honeywell zone valve motor - morphed into add on wood boilerHi, my house have 6 zone and one of the Honeywell zone valve seem not to be working. I was suggested by the plumber that i ha...
Replacing honeywell t8411r heat pump thermostat
Replacing Honeywell T8411R Heat Pump ThermostatHi, I'm looking to replace an old Honeywell T8411R Heat Pump Thermostat with something with similar wiring so I can do it myself. Any suggestion? Tha...
Replacing oil burner primary control
replacing oil burner Primary ControlI'd like to replace my old-style primary control with a new electronic version - it's a regular old Beckett burner, with the control mounted on top of a junctio...