Friday, February 28, 2014

Rv furnace

RV Furnace


I picked up an older model Coleman 4016 RV Furnace used at an auction the unit has had very little use looks almost new inside out. I bought it to replace an old peerless furnace that was original equipment in my trailer. the peerless furnace looks like a round metal can with a round plate bolted to the bottom that has a single round burner, as well as the thermo couple pilot assy. this unit uses an old honeywell control. the problem I am having with the peerless furnace, is in the cold weather, when the furnace thermostat clicks in sometimes the burner does not ignite right away causing the chamber to fill with propane, the result being a contained explosion within the chamber when it finaly does ignite, the force of the explosion blows out the pilot light so once the trailer reaches temp the thermostat snaps out again, the unit is shut down because the pilot has gone out. I asked about this at an RV supply shop they told me the gas control was worn out, they sold me a new control (as the original honeywell control was no longer available they sold me a different brand control) this new control made the problem worse the contained explosions became more severe so I put the old control back on just used it with the thermostat cranked up full. I was just wondering what causes this problem ? Back to the coleman 4016 I have all the parts for this furnace I have hooked it up to propane tested it, it works fine. however I did not get an installation manual with this furnace I am trying to find information regarding minimum clearence to combustable materials, as the furnace mounts in the bottom of a closet. if anyone knows what the minimum clearence requirements are for these older coleman RV furnaces please pass them along Thanks Roger Hello: Roger The most likely cause for the delayed ignition in the peerless unit is restricted burner ports. The ports are the holes in the burner head. If the burner head is in good condition, cleaning out the holes should correct the condition of delayed ignition. Delayed ignition is when the gas does not light immediately as it comes out of the burner. There are most likely also ignition ports which light the gas from the pilots flame first. These holes will be smaller than the main burner holes and located directly in front of the pilot flame or very nearby. Cleaning them also will correct the delayed ignition. The pilots flame must also be all blue and burning cleanly, no yellow not even in the tip of the flame. A hot burning pilot is essential to allow proper ignition. In reply to the questions for the coleman 4016. I do not know the clearance requirements nor where they can be obtained specifically. To many factors to consider to be positive. Plenty depends on the space the unit will be operated in, the local codes, construction materials in the enclosure the unit will be installed in, the environment the unit will be used in, etc. A visit to your local building and safety department may provide the needed information for general installations. Regards Good Luck, Web Host Multiple Topic Moderator. TCB4U2B2B Company Enterprises. Energy Conservation Consultant Gas Appliance Diagnostics Technician.








Related Posts:




  • Trane xl 90 furnace with ignition problem

    Trane XL 90 Furnace with ignition problemTrane XL 90 gas-fired condensing furnace Model TUC0808942A1 Ignition controller White Rogers Model 50E47-060 Digital Thermostat RiteTemp 4 days ago, the fu...


  • Using universal honeywell gas igniter for amana furnace

    Using universal (Honeywell) gas igniter for Amana furnaceCan I use the universal (Honeywell) gas igniter to replace the original igniter on my Amana furnace (model GUVA070BX40)? The gas valve on t...


  • Thermostat wont turn furnace on

    Thermostat won't turn furnace onHello. I bought an old house and one of its rooms is equiped with a direct-vent gas furnace (Perfection-Schwank, Model ASV712RTN Version T). The house is built in 1...


  • Rv furnace pilot going out

    RV Furnace Pilot going outThe pilot light on my RV furnace goes out. The flame lights fine; however after a period of time it goes out. Last week it was going out every other day or once a day. No...


  • Troubleshoot goodman gmp0753 gas furnace

    Troubleshoot Goodman GMP075-3 gas furnaceMy heating system consists of a gas furnace and an electric heat pump. The heat pump is functioning properly, but the furnace itself will not kick in when...